Performance comparison between LWE-131 (old) and GE-100 (new) oscillators

Data represent performance observed in the past few weeks under optimum temperature conditions. Stability of new oscillator includes temporary support and transport optics, and no enhanced temperature and acoustic noise isolation.

  Phase jitter* Phase drift Power jitter Power drift Pointing jitter Pointing drift
LWE-131 ~200 fs rms 0.5 ps/hour

3 ps/day

<0.4% rms up to 10%/day 1.5 mradian rms 20 mradian/day
GE-100 ~200 fs rms 0.5 ps/hour

6 ps/day

<0.1% rms 2.5%p-p/day 0.5 mradian rms 10 mradian/day

Jitter is a shot-to-shot measurement with statistics calculated over a few minutes.

* Phase jitter measurement has lower frequency limit of a few Hz.

Drift is measured over hours or days.

  LWE-131 GE-100
Average Power 60 mW 400 mW
Pulse Duration FWHM 20 ps 7 ps
Amplified Pulse Duration FWHM 20 ps 14 ps
Realignment Frequency > daily 2-3 times weekly