ATF line 3 Present stage - Operational with the Ultrafast particle detector, ready to accept the second phase of the Dielectric Wake Field Accelerator experiment. Various parameters of the magnetic elements used at ATF beam lines are summarized in the following tables:

  Aperture Max Current Volt. Drop Slope Eff. Length
BEPC quad 1X 40 mm
25 A
0.06 V/A
22.1 G/cm/A
10.4 cm
BEPC quad 2X 40 mm
25 A
0.1 V/A
22.1 G/cm/A
20.4 cm
SLAC 1X 28 mm
10 A
0.63 V/A
178.0 G/cm/A
10.16 cm
SLAC 1X 28 mm
10 A
1.1 V/A
181.5 G/cm/A
20.32 cm
6Q40 "Small" 40 mm
10 A
0.63 V/A
50 G/cm/A
7.6 cm

  
Aperture
Maximum Current
Voltage Drop
Slope (see calibration curves)
Effective Length
Dipole 20 deg..   60 A
0.19 V/A
52.4 G/A
40.0 cm
<
Spectrometer dipole 0-8 deg. 30 mm
         24.0 cm
Solenoid 80 mm
200 A
0.1 V/A
14.0 G/A
19.5 cm
Steering coils:
            
Inside solenoid IN/OUT 40 mm
1 A
  49.97/40.83 G/A
10.2/10.5 cm
"Slim" trim 70 mm
4A   25 G/A
0.8 cm
"Old" trim    5A    7 G/A
17 cm