Beam Parameters
-
Electron beam energy 25 to 76 MeV
-
Temporal structure:
Macropulse length: 3 microseconds.
Macropulse repetition rate from under 1 PPS to 3 PPS.
Micropulse repetition period 12.25 ns or 24.5 ns.
Micropulse length variable from about 1 ps FWHM to 10 ps FWHM.
-
Electron beam charge continuously variable.
Single micropulse charge from zero to a few nanoculombs.
Bunch train charge up to about 10 nanoculombs.
-
Electron beam rms normalized emittance: See "Measured
normalized rms emittance as a function of charge" below. The
emittance depends on various conditions, e.g. peak current, gun field,
microbunch length etc. At 1 nC we have measured the emittance at 2.6
mm mrad (rms normalized) at a bunch length of 10 ps FWHM. The local
emittance (Slice Emittance) is smaller, measured 1.4 mm mrad for a
slice out of the 1 nC bunch.
-
Stability (approx.) 1 ps in short term phase, 1% of
beam diameter pointing, 1%-2% relative charge.
-
Some of the measured results below have been presented
at
D.T. Palmer, X.-J. Wang, R.H. Miller, I. Ben-Zvi, C. Pellegrini, J.
Sheehan, J. Skaritka, H. Winick, M. Woodle and V. Yakimenko, Commissioning
Results of the Next Generation Photoinjector, Proc. 7th Advanced Accelerator
Concepts Workshop, Lake Tahoe, Oct. 13-18, 1996
-
-
-
-
-
-
-