Experiments: Completed / Terminated

Superconducting Micro-undulator FEL Experiment

 

Wound yokes of the superferric wigglers used in the Free-Electron Laser
experiments at the Accelerator Test Facility. The top yoke is the
1.8 cm period, parabolic pole-face, radiator wiggler of the High-Gain-Harmonic
Generation FEL. It is 25 cm long. The bottom yoke is a 20 cm long, 8.8 mm
period section of the Microundulator FEL Oscillator experiment. The
operating field of this wiggler is 0.5 Tesla at a gap of 4.4 mm. Both
yokes are precision machined, so that very low field errors are achieved
without any shimming or trimming.

Top of Page

Last Modified: December 3, 2007
Please forward all questions about this site to: Christina Swinson