Safety & Health Services Division, ESH ALD Office, and ESH Administrative Group
ISM, EMS, OSH Information
Integrated Management System (ISM) & Environmental Management System (EMS
14001)
Occupational Safety & Health Management System (OSH, OHSAS 18001)
SHSD
OSH / EMS / ISM Homepage
|
SHSD FRAs |
SHSD Facility Risk Assessments [Word] |
|
|
Rank |
Rev/Date |
|
Office & Lab Occupancy: Building 120 and Trailer T-503. The SE Group occupies 7 offices,
the IH Group occupies 15 offices, SM Group occupies 2 offices, the SHSD Manager
occupies 2 office, the ESH&Q Administration Group has 6 offices, 2 copy/fax rooms, 1 kitchen, and
3 bathrooms. T-503 has 1room for ergonomic equipment demonstration,
1storage closet and 2 offices. The rooms in
Building 120 are equipped with fire
suppression systems (sprinkler system) and the building has
adequate emergency lighting and emergency exit paths for the current
occupancy load. The current facilities are appropriate for the
operations conducted within them.
The IH Group has some operations
with a potential for hazards above the administrative/clerical/
office type of risk. These operations occur
in Room
1-19 (Wet Lab), Room 1-24 (Calibration/meter storage room). These rooms have appropriate
facilities and conditions to allow safe operations. Corrosive
chemicals use may occur infrequently in 1-19 and it has an eyewash/safety
shower and exhausting laboratory hood. |
SHSD-FRA-01 |
Low |
3: 02/27/08 |
|
HEPA Filter Testing
in Building 801: A small part of Building 801 is used for HEPA
filter testing of vacuum cleaners. The testing process involves
a non-toxic aerosol and electronic test equipment with on moving
parts. Compressed gas is used. The building has adequate
emergency lighting and emergency exit paths for the IH Group
operation. Safety shower/eye wash equipment is available in the
vicinity of the operation, but is not required for this level of
hazard. |
SHSD-FRA-02 |
Medium |
2:
12/13/06 |
|
CMS Team in Building 98: CMS
team members frequent and
conduct work in T-98 (process incoming chemical containers).
Safety shower/eye wash equipment is available in the vicinity of the
operation. |
see F&O Directorate |
Medium |
-- |
|
Respirator Fit Testing in Building 490:
SHSD staff or contractors conduct respirator fit testing and
disinfect the respirators used in fit testing with one area of
Building 490. |
see
Life Sciences Directorate |
Low |
-- |
SHSD JRAs
|
SHSD Job Risk Assessments [Word] |
SHSD Environmental Evaluations [Word] |
|
|
Safety Risk |
Re#/Date |
SOEE# |
Title/Aspect |
Rev/Date |
|
HEPA
Filter Surveillance Testing in-place systems & vacuum cleaners |
SHSD-JRA-01
|
Medium |
1:
05/17/07 |
SHSD-EMS-01 |
HEPA Filter Testing |
1: 09/19/06 |
|
Exhaust
ventilation testing including Air Current Indicator Tubes, SF6
Tracer Gas, velometers, etc. |
SHSD-JRA-02 |
Medium |
1:
02/27/08 |
SHSD-EMS-02A |
Air Current Indicator Tubes |
2: 03/14/07 |
|
SHSD-EMS-02B |
SF6 Tracer Gas Studies |
1: 09/19/06 |
|
IH Lab work: processing and shipping samples,
meter repair & calibrations in the IH Lab
|
SHSD-JRA-03
|
Medium |
1:
02/27/08 |
SHSD-EMS-03A |
Meter Calibration with Standard Gas
Mixtures |
2: 06/18/07 |
|
SHSD-EMS-03B |
Battery Disposal |
1: 09/19/06 |
|
Perchlorate Analysis
& Peroxide Testing: field testing and lab analysis for
perchlorates and peroxides.
|
SHSD-JRA-04 |
High |
2:
07/21/08 |
SHSD-EMS-04 |
Perchlorate Testing |
1: 09/19/06 |
|
Exposure
Monitoring with Indicator Tubes, Adsorbent Tubes, Filters, Gas
Detection Meter Sensors, & Microbial plates for Non-ionizing
Radiation, Noise, Perchlorate Testing of hoods and exhaust systems,
Surface Wipes for Chemicals/Metals, Hazards in the
Environment Sampling, Heat Stress site monitoring, Surface
Adhesion/Slip, thermal scan of electronic equipment, etc. |
SHSD-JRA-05 |
Medium |
3:
01/05/07 |
SHSD-EMS-05A |
Air Sampling With Indicator Tubes |
1: 09/19/06 |
|
SHSD-EMS-05B |
Air Sampling With Adsorbent Tubes
Or Filter |
1: 09/19/06 |
|
SHSD-EMS-05C |
Gas Detection Meter Sensors |
1: 09/19/06 |
|
SHSD-EMS-05D |
Surface Wipe Sampling for
Chemicals/Metals |
1: 09/19/06 |
|
SHSD-EMS-05E |
Microbial Plate Decontamination |
2: 06/18/07 |
|
SHSD-EMS-05F |
TSI Model 3007 Condensation
Particle Counter |
1: 09/19/06 |
|
Inspections: Tier 1,
ERE, ORE, BORE; Sanitation Inspections,
Laser Inspections |
SHSD-JRA-06 |
Low |
2:
02/27/08 |
SHSD-EMS-06 |
[Not Assigned] |
-- |
|
Hazardous Waste Operations/ CERCLA Site
Characterizations |
SHSD-JRA-07 |
Low |
1:
04/16/06 |
SHSD-EMS-07 |
[Not Assigned] |
-- |
|
Emergency Response |
SHSD-JRA-08 |
High |
1:
02/27/08 |
SHSD-EMS-08 |
Mercury Spill Clean-Up Supplies |
1: 09/19/06 |
|
Inspections of Construction projects. |
SHSD-JRA-09 |
Medium |
0:
04/05/06 |
SHSD-EMS-09 |
[Not Assigned] |
-- |
|
Investigations: Accident Investigations, ORPS
investigations, and Critiques. |
SHSD-JRA-10 |
Medium |
0:
05/31/06 |
SHSD-EMS-10 |
[Not Assigned] |
-- |
|
Chemical Management System- Barcoding of Chemicals at Receiving
Warehouse & at other facilities |
SHSD-JRA-11
|
Medium |
1:
05/17/07 |
SHSD-EMS-11 |
CMS- Coding
of Chemicals at Receiving Warehouse |
1: 09/19/06 |
|
Respirator Fit Testing |
SHSD-JRA-12 |
Low |
1:
05/17/06 |
SHSD-EMS-12A |
Quantitative Fit Testing |
1: 09/19/06 |
|
SHSD-EMS-12B |
Cleaning of Fit Test Respirators |
1: 09/19/06 |
|
Business travel |
Site Travel |
Low |
-- |
SHSD-EMS-13 |
[Not Assigned] |
-- |
|
Administration, Professional & Office Work |
SHSD-JRA-14 |
Low |
2:
05/10/07 |
SHSD-EMS-14 |
Office and Administrative Work |
0: 12/05/07 |
|
Outdoor Field Sampling for Natural Hazards
in the Environment |
SHSD-JRA-15 |
Medium |
1:
12/31/06 |
SHSD-EMS-15 |
Isopropanol Preservation of ticks |
1: 09/19/06 |
|
Ozone Generation for IAQ Remediation |
SHSD-JRA-16 |
High |
1:
05/17/07 |
SHSD-EMS-16 |
Ozone generation in the remediation
of indoor air quality complaints. |
2: 06/18/07 |
|
Metal Surface Monitoring with XRF |
SHSD-JRA-17 |
High |
0: 05/06/08 |
SHSD-EMS-17 |
[Not Assigned] |
-- |
|
Flammable Storage Cabinet Inspections |
SHSD-JRA-18 |
High |
0: 08/04/08 |
SHSD-EMS-18 |
[Not Assigned] |
-- |
SHSD
OSH / EMS / ISM Homepage
Last Modified: August 18, 2008 Please forward all questions about this site to:
SHSD Admin
|