Data Conversions

  • 28.8 Liter/hour of liquid helium = 1 g/s
  • One 50,000 SCF tube trailer equals ~1840 L (486 gallon) of liquid helium
  • 1 g/s helium ~370 SLPM (St. Liter Per Min.) ~780 SCFH (St. Cubic Foot per Hour)

Cryogenic Equipment 

  • For the 10,000 L liquid helium storage dewar, liquid volume is ~22 gallon / inch

Vertical Test Dewers

               
Vertical Diameter Depth Volume Design
Test             Pressure*
Dewer cm inch m ft L gallon psi
               
2 61 24 6.1 20 1779 470 118
3 71 28 6.1 20 2422 640 50
4 60 24 2.7 8.8 753 199 65
5 61 24 2.7 9.0 801 212 11
6 61 24 2.7 8.8 786 208 11
               
*Calculation for design pressure does not include top plate
In general, top plate is much thicker than bottom plate.
Design pressure does not take insulating vacuum into account.

 

Design Conditions for Compressors in B902
           
  MYCOM   Dunham-Bush   Sullair 350
  (2 Stages)   (2 Stages)   (Single Stage)
           
Flow rate - g/s 160   128   51
Suction          
    pressure - atm 1.07   1   1.05
    temperature - K 294   303   300
Discharge          
    pressure - atm 18   14.5   18
    temperature - K         305
Interstage          
    pressure - atm 5.1   3.8   N.A.
Motor          
    Total - HP 750   700   350
    1st Stage - HP 400   2 x 200    
    2nd Stage - HP 350   300    
           
Model - 1st Stage 320S   2510 DHHOLOC    
      2512 DHHOLOC    
Model - 2nd Stage 200S   2015 DHLOLOC    
Model -         C20LA704-48-350HP
           

   