Design Parameters of the 1st Magnet
Dual aperture 2-in-1 common coil design
40 mm aperture (can be changed)
150 mm spacing between the two bores
40 mm coil bend radius in the ends
Straight section length 0.5 meter; overall length ~ 1 meter
~13 mm wide cable made with existing Nb3Sn ITER conductor
Only 7-8 tesla field with this conductor
Two double pancake coils with one end-spacer