Coil Tests
Danfysik will perform the following tests on the coils:
Pre-impregnation tests:
- Obstruction of coolant flow test
- Test of turn-to-turn insulation
- Test of leakage under pressure (up to 360 psig)
Post-impregnation tests:
- Test of coil-to-earth insulation at 2000 VDC (leakage current less than 20 microA).
- Test of turn-to-turn insulation
- Coil resistance
- Water flow
- Water temperature rise at 600A