Date: Mon, 22 Mar 1999 18:12:35 +0100 (MET) From: Heinz Pernegger <Heinz.Pernegger@cern.ch> To: Andrzej Olszewski <Andrzej.Olszewski@ifj.edu.pl>
Hi Andrzej, About the positive drift of the pedestals. During the testbeam we had very (!) low occupancy and the using a 3 sigma cut also reduces the signal, so I am a little worried if you already see a shift. I think there is a way of finding out if it is connected to signals coming from hits or if it is an artifact of the processing: In the low energy part we also used the paddle counter (overlapping all Si active area) and the finger counter (1x1 cm2) in coincidence. So only the area behind the finger counter should have hits, the rest should have no signals coming from particle. Select some chips in this "no-trigger" area may answer the question for the positve going pedestals maybe. Run 63 (285meV/c pion neg.) is one of these runs (in the log book you maybe find aditional runs) Cheers Heinz