Factory Acceptance Tests
Factory Acceptance tests were conducted on Oct 1 & 2 @ Danfysik
Voltage drop, Pressure drop, Temperature rise were measured. All according to Specs
At 1/7 of the nominal magnet current:
- B = 0.4 T in center
- Field is uniform, no surprises
No measurable deflection at this reduced current setting.